FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource ValueSet/FHIR Server from package de.netzwerk-universitaetsmedizin.ebm-cpg#current (281 ms)

Package de.netzwerk-universitaetsmedizin.ebm-cpg
Type ValueSet
Id Id
FHIR Version R5
Source https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/https://build.fhir.org/ig/CEOsys/cpg-on-ebm-on-fhir/ValueSet-vs-mii-icu-code-observation-beatmung-loinc.html
Url https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-LOINC
Version 1.0.0
Status active
Date 2022-01-06
Name VS_MII_ICU_Code_Observation_Beatmung_LOINC
Title VS MII ICU Code Observation Beatmung [LOINC]
Experimental False
Realm uv
Authority hl7
Description Dieses ValueSet enthält Codes für die im Kontext einer Beatmung eingestellten oder gemessenen Parametern.

Resources that use this resource

StructureDefinition
recommendation-plan Recommendation Plan
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/parameter-von-beatmung SD MII ICU Parameter von Beatmung

Resources that this resource uses

CodeSystem
http://loinc.org LOINC Code System
http://loinc.org LOINC codes used in this IG


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet vs-mii-icu-code-observation-beatmung-loinc

  • Include these codes as defined in http://loinc.org
    CodeDisplay
    50984-4Horowitz index in Arterial blood
    33438-3Breath rate mechanical --on ventilator
    19839-0Breath rate spontaneous --on ventilator
    19840-8Breath rate spontaneous and mechanical --on ventilator
    76334-2Inspiratory time setting Ventilator
    76187-4Expiratory hold time setting Ventilator
    75931-6Inspiration/Expiration time Ratio
    20112-9Tidal volume setting Ventilator
    76222-9Tidal volume Ventilator --on ventilator
    20116-0Tidal volume.spontaneous --on ventilator
    76009-0Inspired minute Volume during Mechanical ventilation
    20118-6Tidal volume.spontaneous+mechanical --on ventilator
    76190-8High pressure hold time setting Ventilator
    76229-4Low pressure hold time setting Ventilator
    76275-7Inspiratory flow setting Ventilator
    60794-5Inspiratory gas flow Respiratory system airway --on ventilator
    60792-9Expiratory gas flow Respiratory system airway --on ventilator
    19994-3Oxygen/Total gas setting [Volume Fraction] Ventilator
    71835-3Oxygen/Gas total [Pure volume fraction] Inhaled gas
    3147-6Oxygen [Partial pressure] in Exhaled gas
    76530-5Mean pressure Respiratory system airway --on ventilator
    76531-3Pressure.max Respiratory system airway --on ventilator
    60827-3Dynamic lung compliance
    76248-4PEEP Respiratory system --on ventilator
    76154-4Airway pressure delta --on ventilator
    20056-8Airway pressure --at mean expiratory flow on ventilator
    20060-0Airway pressure --at zero inspiratory flow on ventilator
    19891-1Carbon dioxide [Partial pressure] in Exhaled gas --at end expiration
    20079-0Pressure support setting Ventilator

Source

{
  "resourceType" : "ValueSet",
  "id" : "vs-mii-icu-code-observation-beatmung-loinc",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet vs-mii-icu-code-observation-beatmung-loinc</b></p><a name=\"vs-mii-icu-code-observation-beatmung-loinc\"> </a><a name=\"hcvs-mii-icu-code-observation-beatmung-loinc\"> </a><a name=\"vs-mii-icu-code-observation-beatmung-loinc-en-US\"> </a><ul><li>Include these codes as defined in <a href=\"http://loinc.org\"><code>http://loinc.org</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"https://loinc.org/50984-4/\">50984-4</a></td><td>Horowitz index in Arterial blood</td></tr><tr><td><a href=\"https://loinc.org/33438-3/\">33438-3</a></td><td>Breath rate mechanical --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19839-0/\">19839-0</a></td><td>Breath rate spontaneous --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19840-8/\">19840-8</a></td><td>Breath rate spontaneous and mechanical --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76334-2/\">76334-2</a></td><td>Inspiratory time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76187-4/\">76187-4</a></td><td>Expiratory hold time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/75931-6/\">75931-6</a></td><td>Inspiration/Expiration time Ratio</td></tr><tr><td><a href=\"https://loinc.org/20112-9/\">20112-9</a></td><td>Tidal volume setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76222-9/\">76222-9</a></td><td>Tidal volume Ventilator --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/20116-0/\">20116-0</a></td><td>Tidal volume.spontaneous --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76009-0/\">76009-0</a></td><td>Inspired minute Volume during Mechanical ventilation</td></tr><tr><td><a href=\"https://loinc.org/20118-6/\">20118-6</a></td><td>Tidal volume.spontaneous+mechanical --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76190-8/\">76190-8</a></td><td>High pressure hold time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76229-4/\">76229-4</a></td><td>Low pressure hold time setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/76275-7/\">76275-7</a></td><td>Inspiratory flow setting Ventilator</td></tr><tr><td><a href=\"https://loinc.org/60794-5/\">60794-5</a></td><td>Inspiratory gas flow Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/60792-9/\">60792-9</a></td><td>Expiratory gas flow Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19994-3/\">19994-3</a></td><td>Oxygen/Total gas setting [Volume Fraction] Ventilator</td></tr><tr><td><a href=\"https://loinc.org/71835-3/\">71835-3</a></td><td>Oxygen/Gas total [Pure volume fraction] Inhaled gas</td></tr><tr><td><a href=\"https://loinc.org/3147-6/\">3147-6</a></td><td>Oxygen [Partial pressure] in Exhaled gas</td></tr><tr><td><a href=\"https://loinc.org/76530-5/\">76530-5</a></td><td>Mean pressure Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76531-3/\">76531-3</a></td><td>Pressure.max Respiratory system airway --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/60827-3/\">60827-3</a></td><td>Dynamic lung compliance</td></tr><tr><td><a href=\"https://loinc.org/76248-4/\">76248-4</a></td><td>PEEP Respiratory system --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/76154-4/\">76154-4</a></td><td>Airway pressure delta --on ventilator</td></tr><tr><td><a href=\"https://loinc.org/20056-8/\">20056-8</a></td><td>Airway pressure --at mean expiratory flow on ventilator</td></tr><tr><td><a href=\"https://loinc.org/20060-0/\">20060-0</a></td><td>Airway pressure --at zero inspiratory flow on ventilator</td></tr><tr><td><a href=\"https://loinc.org/19891-1/\">19891-1</a></td><td>Carbon dioxide [Partial pressure] in Exhaled gas --at end expiration</td></tr><tr><td><a href=\"https://loinc.org/20079-0/\">20079-0</a></td><td>Pressure support setting Ventilator</td></tr></table></li></ul></div>"
  },
  "url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/Code-Observation-Beatmung-LOINC",
  "version" : "1.0.0",
  "name" : "VS_MII_ICU_Code_Observation_Beatmung_LOINC",
  "title" : "VS MII ICU Code Observation Beatmung [LOINC]",
  "status" : "active",
  "experimental" : false,
  "date" : "2022-01-06",
  "publisher" : "https://www.medizininformatik-initiative.de",
  "description" : "Dieses ValueSet enthält Codes für die im Kontext einer Beatmung eingestellten oder gemessenen Parametern.",
  "compose" : {
    "include" : [
      {
        "system" : "http://loinc.org",
        "concept" : [
          {
            "code" : "50984-4",
            "display" : "Horowitz index in Arterial blood"
          },
          {
            "code" : "33438-3",
            "display" : "Breath rate mechanical --on ventilator"
          },
          {
            "code" : "19839-0",
            "display" : "Breath rate spontaneous --on ventilator"
          },
          {
            "code" : "19840-8",
            "display" : "Breath rate spontaneous and mechanical --on ventilator"
          },
          {
            "code" : "76334-2",
            "display" : "Inspiratory time setting Ventilator"
          },
          {
            "code" : "76187-4",
            "display" : "Expiratory hold time setting Ventilator"
          },
          {
            "code" : "75931-6",
            "display" : "Inspiration/Expiration time Ratio"
          },
          {
            "code" : "20112-9",
            "display" : "Tidal volume setting Ventilator"
          },
          {
            "code" : "76222-9",
            "display" : "Tidal volume Ventilator --on ventilator"
          },
          {
            "code" : "20116-0",
            "display" : "Tidal volume.spontaneous --on ventilator"
          },
          {
            "code" : "76009-0",
            "display" : "Inspired minute Volume during Mechanical ventilation"
          },
          {
            "code" : "20118-6",
            "display" : "Tidal volume.spontaneous+mechanical --on ventilator"
          },
          {
            "code" : "76190-8",
            "display" : "High pressure hold time setting Ventilator"
          },
          {
            "code" : "76229-4",
            "display" : "Low pressure hold time setting Ventilator"
          },
          {
            "code" : "76275-7",
            "display" : "Inspiratory flow setting Ventilator"
          },
          {
            "code" : "60794-5",
            "display" : "Inspiratory gas flow Respiratory system airway --on ventilator"
          },
          {
            "code" : "60792-9",
            "display" : "Expiratory gas flow Respiratory system airway --on ventilator"
          },
          {
            "code" : "19994-3",
            "display" : "Oxygen/Total gas setting [Volume Fraction] Ventilator"
          },
          {
            "code" : "71835-3",
            "display" : "Oxygen/Gas total [Pure volume fraction] Inhaled gas"
          },
          {
            "code" : "3147-6",
            "display" : "Oxygen [Partial pressure] in Exhaled gas"
          },
          {
            "code" : "76530-5",
            "display" : "Mean pressure Respiratory system airway --on ventilator"
          },
          {
            "code" : "76531-3",
            "display" : "Pressure.max Respiratory system airway --on ventilator"
          },
          {
            "code" : "60827-3",
            "display" : "Dynamic lung compliance"
          },
          {
            "code" : "76248-4",
            "display" : "PEEP Respiratory system --on ventilator"
          },
          {
            "code" : "76154-4",
            "display" : "Airway pressure delta --on ventilator"
          },
          {
            "code" : "20056-8",
            "display" : "Airway pressure --at mean expiratory flow on ventilator"
          },
          {
            "code" : "20060-0",
            "display" : "Airway pressure --at zero inspiratory flow on ventilator"
          },
          {
            "code" : "19891-1",
            "display" : "Carbon dioxide [Partial pressure] in Exhaled gas --at end expiration"
          },
          {
            "code" : "20079-0",
            "display" : "Pressure support setting Ventilator"
          }
        ]
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.